Huawei Switches Guide
Huawei Switches: Campus and Data Center Buying Guide
Huawei switches cover campus access, aggregation, core, and data center leaf-spine networks. What really determines whether it can be used is not a series abbreviation, but the complete model, port media, PoE budget, software version, authorization and optical module combination.
This article is intended for enterprise buyers, integrators, and maintenance projects. It provides a verification path from network role to procurement acceptance, and does not regard all CloudEngine devices as interchangeable.

Quick Reference
Huawei switch quick reference
| question | short answer |
|---|---|
| Campus network? | First, it is divided according to access, aggregation, core and terminal power supply. |
| Data center? | Focus on leaf spine role, port speed, cache and redundancy. |
| Is the model enough? | The complete suffix and part number must be provided. |
| How is PoE calculated? | Port standards, single port requirements and complete device budget are calculated together. |
| Are optical modules universal? | Not universal by default, check by port and software compatibility table. |
| Discontinued equipment? | Verify status, authorization and replacement risk first before negotiating price. |

Overview
Start with a network character first, not a model first
A good switch inventory should work backward from service, topology, and site constraints. If you first select a familiar series and then add ports, power supplies, and authorizations, you will most likely end up with the result that ”the device can be powered on, but cannot be delivered as designed.”
- Define access, convergence, core, or spine roles.
- Statistics on port number, media, speed and future growth.
- Calculate PoE, uplinks, entries, and redundancy requirements.
- Determine software version, management method and authorized functions.
- Lock the complete model number, part number and supporting materials.
- Accept equipment and accessories according to the unified test table.
01 · Network scene
What is the difference between campus switches and data center switches?

Campus networks are oriented to users, phones, cameras, wireless APs and office terminals, and usually pay more attention to copper cable access, PoE, authentication, policy and easy operation and maintenance. Data center networks connect servers and storage and pay more attention to high-density optical ports, low latency, east-west bandwidth, leaf-spine expansion and device-level redundancy.
| comparison item | campus network | data center network |
|---|---|---|
| common roles | access, convergence, core | Leaf、Spine、Border |
| Typical terminal | PC, AP, IP phone, camera | Server, storage, computing cluster |
| Port focus | GE/Multi-GE copper port and PoE | 10/25/40/100GE and higher speed optical ports |
| Operation and maintenance focus | Access, user policy, wireless collaboration | Automation, Telemetry, Virtual Networks, Fault Domains |
| High availability | Stacking, CSS, link redundancy | M-LAG, ECMP, dual plane design |
Boundaries are not absolute. Huawei’s official product catalog states that some CloudEngine data center switches are also used in high-end campuses; whether they are suitable or not should be judged based on interfaces, functions, management platforms, power consumption, and overall architecture.
02 · Product family
How to position Huawei CloudEngine switch family
For a procurement list, browse the Huawei switch catalog with current and legacy model references. Use the complete model and Part Number for each switch or Huawei replacement spare; the discontinued Huawei equipment sourcing guide covers replacement identity and condition checks.

| Official family example | common locations | Key points when purchasing |
|---|---|---|
| CloudEngine S5735-L-V2 | Park access | Copper/optical port, PoE suffix, uplink and stacking |
| CloudEngine S6730-H | High-density 10GE access or aggregation | SFP+ quantity, QSFP28 speed and RTU |
| S8700 / S12700H / S16700 | Campus convergence or core | Chassis, main control, switching network board, service board and power supply |
| CloudEngine 6800 / 8800 / 9800 | Data center fixed or high-density switching | Leaf spine roles, port shapes, air ducts and software |
| CloudEngine 16800 | Large data center core | Frame generations, slots, boards, switching capacity and redundancy |
Families can only help get into the right range, not replace the BOM. For fixed switches, you need to confirm the complete device model, power supply and fan; for modular switches, you need to disassemble and check the chassis, main control, switching network board, service board, optical module and authorization.
03 · Exact model
Why the full model number is more important than the series name

The S5735, S6730 or CE68 are just family entries. There may be 24/48 ports, copper/optical ports, PoE/non-PoE, GE/10GE uplinks, AC/DC power supplies, different air ducts, and different generations in the same family. The quotation only writes the series, leaving the key differences until after delivery.
| Representative model | Confirmable hardware direction | Check before placing an order |
|---|---|---|
| S5735-L24T4S-A-V2 | 24 GE copper ports, 4 GE SFP, the above official list is non-PoE | Power supply, software version, stacking and local sales status |
| S5735-L24P4S-A-V2 | Same-class 24-port PoE version with 4 GE SFPs | complete device PoE budget and power conditions |
| S5735-L24P4XE-A-V2 | 24 GE copper ports, 4 10GE SFP+, 2 stacking ports, supporting PoE | Uplink modules, stacking lines and power budget |
| S6730-H48X6C | 48 10GE SFP+, 6 40/100GE QSFP28 | Is the 100GE RTU activated and the power supply included? |
Important:The information in the table comes from the current official product pages and materials and is used to explain the verification method. Part numbers, software versions, market availability and authorization status will change, and the purchase contract should still state the complete BOM and acceptance criteria.
04 · Interface and performance
How to read ports, uplinks, switching capacity and forwarding performance

| Project | Answered questions | Common misunderstandings |
|---|---|---|
| fixed port | Does the terminal use copper cable or optical fiber? What is the speed? | Treat SFP form factor as fixed rate |
| uplink port | How much bandwidth can be provided when connecting to the aggregation/core | Ignore sharing, splitting and licensing conditions |
| switching capacity | Theoretical capabilities of internal processing of equipment | Only compare the largest numbers without looking at the test instructions |
| Packet forwarding rate | Processing capabilities for small package scenarios | Directly sort different test calibers |
| MAC/ARP/routing table entries | Whether the network scale exceeds the device boundary | Use port number instead of table entry planning |
| Caching and latency | Burst traffic and data center business performance | Ignore business traffic model |
Port ”exists” does not equal target rate available by default. For example, the QSFP28 port of S6730-H48X6C works in 40GE by default on some part numbers. Upgrading to 100GE requires corresponding RTU and configuration. When purchasing, the port speed, quantity, splitting method, authorization and restart conditions should be written on the same line.
05 · Terminal power supply
PoE, PoE+ and complete device power budget

PoE selection cannot just ask ”whether it is supported”. Terminal startup spikes, cable lengths, ambient temperatures, and dual-power strategies can all change the available budget. A 48-port PoE switch does not mean that 48 ports can supply power at the highest level at the same time.
- Statistics of powered devicesRecord standard and peak power of APs, phones, and cameras.
- Calculate concurrency budgetAdd all active ports together, leaving margin for upgrades and wear and tear.
- Check power moduleConfirm the current power supply quantity, input format and remaining budget after failure.
- Verify wiringCheck the wire diameter, length, termination quality and temperature rise. Do not use short-term testing instead of on-site.
Suffixes such as T, P, and LP in the same series may represent non-PoE, full PoE, or partial port power supply directions, but the naming rules cannot replace the official hardware description. The exact model number should ultimately be checked one by one.
06 · Network capabilities
Layer 2, Layer 3 and campus automation functions

| functional group | Typical requirements | Procurement issues |
|---|---|---|
| Second floor | VLAN, link aggregation, loop protection | Whether the protocol, scale and cross-vendor compatibility are met |
| third floor | Static routing, OSPF, IPv6, etc. | Whether the target version, table entry and license are supported |
| Access and security | 802.1X, MAC authentication, ACL, QoS | How to integrate authentication system and policy distribution |
| virtual network | VXLAN, network segmentation and policy mobility | Which software packages and controllers are required |
| Observability | Telemetry, logs, traffic analysis | Collection platform, authorization and retention period |
| wireless collaboration | AP management, wired and wireless unified strategy | Manageable quantities, versions and resource entitlements |
Just because a feature is listed in the specification sheet does not mean it is ready for use with the factory configuration. When confirming, you should put ”device model + software version + license package + networking mode” together; if iMaster NCE-Campus or a third-party platform is involved, you should also check the platform version and subscription scope.
07 · High availability
Stacking, CSS, M-LAG and redundant design

| way | Basic idea | Design focus |
|---|---|---|
| stack | Multiple fixed switches form a logical device | Number of members, stack ports, bandwidth, upgrades and fault domains |
| CSS | Commonly used for clustering frame-type equipment | Main control, switching network board, link and version requirements |
| M-LAG | Two devices maintain independent control planes and aggregate across devices | Peer-to-peer links, active-active gateways, fault convergence and configuration consistency |
| Link aggregation/ECMP | Share traffic across multiple links or paths | Hashing, path symmetry, protocols and upstream design |
Redundancy is not about more cables being better. Power supplies, uplinks, control planes, management networks, and software upgrades all need to avoid common failures. Huawei has special definitions and applicable conditions for CSS, so the interconnection of any two devices cannot be called CSS.
08·Connection media
Optical modules, DAC, AOC and cabling compatible

| medium | Common uses | must match |
|---|---|---|
| Multimode optical module | In the computer room or short distance to the building | Speed, Wavelength, OM Level, Connector and Distance |
| Single mode optical module | Park backbone and longer distances | Optical budget, wavelength, distance and fiber core at both ends |
| DAC | Short-distance direct connection within the cabinet | Port specifications, lengths, bend radii and compatible coding |
| AOC | Lighter and longer computer room high-speed interconnection | Rate, length, port support and maintenance methods |
| split line | Split a high-speed port into multiple low-speed connections | Device, port, software and split mode support |
When the optical port cannot link, check module support, transmit and receive wavelengths, fiber type, polarity, cleanliness, optical power, port rate and configuration layer by layer. Even if third-party modules are recognized, they do not mean they are supported in all software versions and in all temperature ranges.
09 · Software and Operation and Maintenance
Management methods, software versions and licensing

Switches can be managed via the command line, Web, SNMP, Telemetry, or a centralized platform, but capabilities vary across models and software versions. If an existing network requires unified templates, logs, identity authentication or controller management, management compatibility should be completed before hardware quotation.
| Check items | Need to record | risk |
|---|---|---|
| VRP/system version | Current version, target version, patches and upgrade paths | Function, command, or module support changes |
| Basic/Advanced packages | Purchased package, validity period, binding method | Missing advanced routing, VXLAN or operational capabilities |
| RTU | Port rate or resource is activated | Hardware is present but does not operate at target capabilities |
| Centralized management | Platform version, number of devices and subscriptions | Unable to manage or exceeded authorization |
| Configuration and Account | Factory wipe, administrator rights, backup | Second-hand equipment may have residual configuration or cannot be taken over |
When purchasing discontinued equipment, you must ask whether the authorization is legally transferred with the equipment and whether support from the original account or contract is required. A ”fully functional” description that cannot prove the source or authorization status should not be included in the acceptance conclusion.
10 · Procurement and Substitution
Checklist for purchasing new, used equipment and discontinued models

| stage | Recommended action |
|---|---|
| Requirements definition | Submit topology, port, speed, PoE, protocol, redundancy, environment, country and delivery date |
| Model confirmation | Lock in complete models, part numbers, hardware versions, software and licenses |
| Attachment confirmation | List power supplies, fans, rack ears, cables, optical modules and packaging |
| Supplier verification | Confirm origin, device condition, warranty, return and serial number policies |
| Arrival test | Appearance, startup, ports, power supply, fans, logs, software and licensing |
| Replacement planning | Compare table items, protocols, network management, power supply, wiring and shutdown windows |
For discontinued replacement, you should not just look for new machines with the same ports. Configuration commands, stacking methods, optical modules, air ducts, power supplies, licenses, and network management platforms may all change. If the business must retain the original model, it should also purchase tested backup machines and key power supplies/fans, and save the restorable configuration.
- The quotation indicates the condition of the machine as new, refurbished, second-hand or dismantled.
- Serial number and photo remain consistent before and after payment.
- Test reports correspond to specific equipment and do not use universal samples.
- Securing modules, protecting interfaces and documenting packaging prior to international shipping.

FAQ
Huawei switch FAQs
The answers below are based on the complete model, hardware version, software version, and project conditions.
What are the main types of Huawei switches?
Common procurement areas include campus access, aggregation and core switches, as well as data center leaf-spine switches. Fixed ports scale differently than frame-based devices, and must be classified by network role before comparing complete models.
What is the difference between CloudEngine S-Series and CloudEngine Data Center Series?
The S series is mostly found in campus networks; families such as 16800, 9800, 8800, and 6800 are usually targeted at data centers. However, some high-performance data center models can also enter high-end campuses. Ultimately, it still depends on the design goals and specific specifications.
How to interpret Huawei switch model?
Don’t just look at series abbreviations like S5735, S6730 or CE68. The number of ports, port media, PoE, uplink, generation and power suffix in the complete model will change the hardware and should be subject to the complete device label and official hardware description.
How do I know if my switch supports PoE?
First check whether the complete model is a PoE version, then confirm the per-port standard, complete device PoE budget, number of power modules and current load. The same number of ports does not mean the same power supply.
Are stacking, CSS and M-LAG the same thing?
No. They can both be used to extend or improve availability, but differ in control planes, fault domains, configuration methods, and applicable products. Must be selected according to model, software version and networking target.
Can third-party optical modules be mixed and used?
You cannot judge based on the appearance of the interface alone. Rate, wavelength, distance, fiber type, connector, DOM, encoding and device software compatibility need to be checked and tested on the target port.
What should I check when buying a second-hand or discontinued Huawei switch?
At a minimum, check the complete part number, serial number, appearance, power supply fan, ports, startup status, software version, authorization, configuration clearing, and spare parts availability. Replacement parts should also be provided for critical items.
Will software licensing affect ports or functionality?
possible. High-speed ports, VXLAN, wireless management, or advanced features on some models may be related to RTUs or software packages. Do not equate the presence of a hardware port with the target function being activated.
Can data center switches be used as campus core?
Some products are also suitable for high-end campuses in official materials, but not all data center models are suitable. It is necessary to compare access methods, PoE, operation and maintenance platforms, table items, protocols, redundancy and on-site conditions.
What information should be provided when making a quotation request?
Provide complete model, quantity, old and new status, port and speed, PoE, uplink, software version, authorization, optical module, power supply format, destination country and delivery date. If the model is not determined, please attach the network topology or purchase list.

Summary
Translate network requirements into a complete BOM that can be accepted
- Determine the campus or data center role first, and then enter the appropriate family.
- Use the complete model number, part number and software version instead of the series abbreviation to place your order.
- Put PoE, power supplies, optics, stacking and licensing in the same list.
- Perform unit-by-unit inspections of second-hand and discontinued equipment and prepare replacement plans.
The soundest procurement is not about chasing the biggest specs, but about having every capability proven in the target topology, field power, management platform and acceptance process.
Procurement consultation
Submit your Huawei switch listing
Please indicate the complete model, quantity, ports/PoE, software and authorization, device condition, destination country and delivery date; the topology and number of terminals can be described if the model is not specified. Please do not submit passwords or sensitive configurations on the live network.