Engineers compare switches, optical modules and network requirements based on bill of materials

Overview

Start with a network character first, not a model first

A good switch inventory should work backward from service, topology, and site constraints. If you first select a familiar series and then add ports, power supplies, and authorizations, you will most likely end up with the result that ”the device can be powered on, but cannot be delivered as designed.”

  1. Define access, convergence, core, or spine roles.
  2. Statistics on port number, media, speed and future growth.
  3. Calculate PoE, uplinks, entries, and redundancy requirements.
  4. Determine software version, management method and authorized functions.
  5. Lock the complete model number, part number and supporting materials.
  6. Accept equipment and accessories according to the unified test table.

01 · Network scene

What is the difference between campus switches and data center switches?

Comparison of office campus access cabinets and high-density data center racks

Campus networks are oriented to users, phones, cameras, wireless APs and office terminals, and usually pay more attention to copper cable access, PoE, authentication, policy and easy operation and maintenance. Data center networks connect servers and storage and pay more attention to high-density optical ports, low latency, east-west bandwidth, leaf-spine expansion and device-level redundancy.

comparison itemcampus networkdata center network
common rolesaccess, convergence, coreLeaf、Spine、Border
Typical terminalPC, AP, IP phone, cameraServer, storage, computing cluster
Port focusGE/Multi-GE copper port and PoE10/25/40/100GE and higher speed optical ports
Operation and maintenance focusAccess, user policy, wireless collaborationAutomation, Telemetry, Virtual Networks, Fault Domains
High availabilityStacking, CSS, link redundancyM-LAG, ECMP, dual plane design

Boundaries are not absolute. Huawei’s official product catalog states that some CloudEngine data center switches are also used in high-end campuses; whether they are suitable or not should be judged based on interfaces, functions, management platforms, power consumption, and overall architecture.

02 · Product family

How to position Huawei CloudEngine switch family

For a procurement list, browse the Huawei switch catalog with current and legacy model references. Use the complete model and Part Number for each switch or Huawei replacement spare; the discontinued Huawei equipment sourcing guide covers replacement identity and condition checks.

Comparison of fixed access, fiber aggregation and modular core switches
Official family examplecommon locationsKey points when purchasing
CloudEngine S5735-L-V2Park accessCopper/optical port, PoE suffix, uplink and stacking
CloudEngine S6730-HHigh-density 10GE access or aggregationSFP+ quantity, QSFP28 speed and RTU
S8700 / S12700H / S16700Campus convergence or coreChassis, main control, switching network board, service board and power supply
CloudEngine 6800 / 8800 / 9800Data center fixed or high-density switchingLeaf spine roles, port shapes, air ducts and software
CloudEngine 16800Large data center coreFrame generations, slots, boards, switching capacity and redundancy

Families can only help get into the right range, not replace the BOM. For fixed switches, you need to confirm the complete device model, power supply and fan; for modular switches, you need to disassemble and check the chassis, main control, switching network board, service board, optical module and authorization.

View Huawei enterprise switch product catalog

03 · Exact model

Why the full model number is more important than the series name

Technician scans switch label and checks complete model number with purchase list

The S5735, S6730 or CE68 are just family entries. There may be 24/48 ports, copper/optical ports, PoE/non-PoE, GE/10GE uplinks, AC/DC power supplies, different air ducts, and different generations in the same family. The quotation only writes the series, leaving the key differences until after delivery.

Representative modelConfirmable hardware directionCheck before placing an order
S5735-L24T4S-A-V224 GE copper ports, 4 GE SFP, the above official list is non-PoEPower supply, software version, stacking and local sales status
S5735-L24P4S-A-V2Same-class 24-port PoE version with 4 GE SFPscomplete device PoE budget and power conditions
S5735-L24P4XE-A-V224 GE copper ports, 4 10GE SFP+, 2 stacking ports, supporting PoEUplink modules, stacking lines and power budget
S6730-H48X6C48 10GE SFP+, 6 40/100GE QSFP28Is the 100GE RTU activated and the power supply included?

Important:The information in the table comes from the current official product pages and materials and is used to explain the verification method. Part numbers, software versions, market availability and authorization status will change, and the purchase contract should still state the complete BOM and acceptance criteria.

04 · Interface and performance

How to read ports, uplinks, switching capacity and forwarding performance

RJ45, SFP+, QSFP and management interfaces on enterprise switch front panel
ProjectAnswered questionsCommon misunderstandings
fixed portDoes the terminal use copper cable or optical fiber? What is the speed?Treat SFP form factor as fixed rate
uplink portHow much bandwidth can be provided when connecting to the aggregation/coreIgnore sharing, splitting and licensing conditions
switching capacityTheoretical capabilities of internal processing of equipmentOnly compare the largest numbers without looking at the test instructions
Packet forwarding rateProcessing capabilities for small package scenariosDirectly sort different test calibers
MAC/ARP/routing table entriesWhether the network scale exceeds the device boundaryUse port number instead of table entry planning
Caching and latencyBurst traffic and data center business performanceIgnore business traffic model

Port ”exists” does not equal target rate available by default. For example, the QSFP28 port of S6730-H48X6C works in 40GE by default on some part numbers. Upgrading to 100GE requires corresponding RTU and configuration. When purchasing, the port speed, quantity, splitting method, authorization and restart conditions should be written on the same line.

05 · Terminal power supply

PoE, PoE+ and complete device power budget

Computer room scenario where PoE switches power wireless APs, IP phones, and security cameras

PoE selection cannot just ask ”whether it is supported”. Terminal startup spikes, cable lengths, ambient temperatures, and dual-power strategies can all change the available budget. A 48-port PoE switch does not mean that 48 ports can supply power at the highest level at the same time.

  • Statistics of powered devicesRecord standard and peak power of APs, phones, and cameras.
  • Calculate concurrency budgetAdd all active ports together, leaving margin for upgrades and wear and tear.
  • Check power moduleConfirm the current power supply quantity, input format and remaining budget after failure.
  • Verify wiringCheck the wire diameter, length, termination quality and temperature rise. Do not use short-term testing instead of on-site.

Suffixes such as T, P, and LP in the same series may represent non-PoE, full PoE, or partial port power supply directions, but the naming rules cannot replace the official hardware description. The exact model number should ultimately be checked one by one.

06 · Network capabilities

Layer 2, Layer 3 and campus automation functions

Network operation and maintenance personnel monitor VLAN, routing, access control and operating status
functional groupTypical requirementsProcurement issues
Second floorVLAN, link aggregation, loop protectionWhether the protocol, scale and cross-vendor compatibility are met
third floorStatic routing, OSPF, IPv6, etc.Whether the target version, table entry and license are supported
Access and security802.1X, MAC authentication, ACL, QoSHow to integrate authentication system and policy distribution
virtual networkVXLAN, network segmentation and policy mobilityWhich software packages and controllers are required
ObservabilityTelemetry, logs, traffic analysisCollection platform, authorization and retention period
wireless collaborationAP management, wired and wireless unified strategyManageable quantities, versions and resource entitlements

Just because a feature is listed in the specification sheet does not mean it is ready for use with the factory configuration. When confirming, you should put ”device model + software version + license package + networking mode” together; if iMaster NCE-Campus or a third-party platform is involved, you should also check the platform version and subscription scope.

07 · High availability

Stacking, CSS, M-LAG and redundant design

Two switches connected via redundant fiber optics and stacking links and using dual power supplies
wayBasic ideaDesign focus
stackMultiple fixed switches form a logical deviceNumber of members, stack ports, bandwidth, upgrades and fault domains
CSSCommonly used for clustering frame-type equipmentMain control, switching network board, link and version requirements
M-LAGTwo devices maintain independent control planes and aggregate across devicesPeer-to-peer links, active-active gateways, fault convergence and configuration consistency
Link aggregation/ECMPShare traffic across multiple links or pathsHashing, path symmetry, protocols and upstream design

Redundancy is not about more cables being better. Power supplies, uplinks, control planes, management networks, and software upgrades all need to avoid common failures. Huawei has special definitions and applicable conditions for CSS, so the interconnection of any two devices cannot be called CSS.

View Huawei CSS technical description

08·Connection media

Optical modules, DAC, AOC and cabling compatible

SFP and QSFP optical modules, LC fiber, DAC, AOC and cleaning tools
mediumCommon usesmust match
Multimode optical moduleIn the computer room or short distance to the buildingSpeed, Wavelength, OM Level, Connector and Distance
Single mode optical modulePark backbone and longer distancesOptical budget, wavelength, distance and fiber core at both ends
DACShort-distance direct connection within the cabinetPort specifications, lengths, bend radii and compatible coding
AOCLighter and longer computer room high-speed interconnectionRate, length, port support and maintenance methods
split lineSplit a high-speed port into multiple low-speed connectionsDevice, port, software and split mode support

When the optical port cannot link, check module support, transmit and receive wavelengths, fiber type, polarity, cleanliness, optical power, port rate and configuration layer by layer. Even if third-party modules are recognized, they do not mean they are supported in all software versions and in all temperature ranges.

View Huawei optical interface troubleshooting instructions

09 · Software and Operation and Maintenance

Management methods, software versions and licensing

Administrators maintain the switch through the console line and network management interface

Switches can be managed via the command line, Web, SNMP, Telemetry, or a centralized platform, but capabilities vary across models and software versions. If an existing network requires unified templates, logs, identity authentication or controller management, management compatibility should be completed before hardware quotation.

Check itemsNeed to recordrisk
VRP/system versionCurrent version, target version, patches and upgrade pathsFunction, command, or module support changes
Basic/Advanced packagesPurchased package, validity period, binding methodMissing advanced routing, VXLAN or operational capabilities
RTUPort rate or resource is activatedHardware is present but does not operate at target capabilities
Centralized managementPlatform version, number of devices and subscriptionsUnable to manage or exceeded authorization
Configuration and AccountFactory wipe, administrator rights, backupSecond-hand equipment may have residual configuration or cannot be taken over

When purchasing discontinued equipment, you must ask whether the authorization is legally transferred with the equipment and whether support from the original account or contract is required. A ”fully functional” description that cannot prove the source or authorization status should not be included in the acceptance conclusion.

10 · Procurement and Substitution

Checklist for purchasing new, used equipment and discontinued models

Purchase and accept switches, optical modules, power supplies and cables in the warehouse
stageRecommended action
Requirements definitionSubmit topology, port, speed, PoE, protocol, redundancy, environment, country and delivery date
Model confirmationLock in complete models, part numbers, hardware versions, software and licenses
Attachment confirmationList power supplies, fans, rack ears, cables, optical modules and packaging
Supplier verificationConfirm origin, device condition, warranty, return and serial number policies
Arrival testAppearance, startup, ports, power supply, fans, logs, software and licensing
Replacement planningCompare table items, protocols, network management, power supply, wiring and shutdown windows

For discontinued replacement, you should not just look for new machines with the same ports. Configuration commands, stacking methods, optical modules, air ducts, power supplies, licenses, and network management platforms may all change. If the business must retain the original model, it should also purchase tested backup machines and key power supplies/fans, and save the restorable configuration.

  • The quotation indicates the condition of the machine as new, refurbished, second-hand or dismantled.
  • Serial number and photo remain consistent before and after payment.
  • Test reports correspond to specific equipment and do not use universal samples.
  • Securing modules, protecting interfaces and documenting packaging prior to international shipping.
Engineers discuss Huawei switch selection, compatibility, and procurement issues

FAQ

Huawei switch FAQs

The answers below are based on the complete model, hardware version, software version, and project conditions.

What are the main types of Huawei switches?

Common procurement areas include campus access, aggregation and core switches, as well as data center leaf-spine switches. Fixed ports scale differently than frame-based devices, and must be classified by network role before comparing complete models.

What is the difference between CloudEngine S-Series and CloudEngine Data Center Series?

The S series is mostly found in campus networks; families such as 16800, 9800, 8800, and 6800 are usually targeted at data centers. However, some high-performance data center models can also enter high-end campuses. Ultimately, it still depends on the design goals and specific specifications.

How to interpret Huawei switch model?

Don’t just look at series abbreviations like S5735, S6730 or CE68. The number of ports, port media, PoE, uplink, generation and power suffix in the complete model will change the hardware and should be subject to the complete device label and official hardware description.

How do I know if my switch supports PoE?

First check whether the complete model is a PoE version, then confirm the per-port standard, complete device PoE budget, number of power modules and current load. The same number of ports does not mean the same power supply.

Are stacking, CSS and M-LAG the same thing?

No. They can both be used to extend or improve availability, but differ in control planes, fault domains, configuration methods, and applicable products. Must be selected according to model, software version and networking target.

Can third-party optical modules be mixed and used?

You cannot judge based on the appearance of the interface alone. Rate, wavelength, distance, fiber type, connector, DOM, encoding and device software compatibility need to be checked and tested on the target port.

What should I check when buying a second-hand or discontinued Huawei switch?

At a minimum, check the complete part number, serial number, appearance, power supply fan, ports, startup status, software version, authorization, configuration clearing, and spare parts availability. Replacement parts should also be provided for critical items.

Will software licensing affect ports or functionality?

possible. High-speed ports, VXLAN, wireless management, or advanced features on some models may be related to RTUs or software packages. Do not equate the presence of a hardware port with the target function being activated.

Can data center switches be used as campus core?

Some products are also suitable for high-end campuses in official materials, but not all data center models are suitable. It is necessary to compare access methods, PoE, operation and maintenance platforms, table items, protocols, redundancy and on-site conditions.

What information should be provided when making a quotation request?

Provide complete model, quantity, old and new status, port and speed, PoE, uplink, software version, authorization, optical module, power supply format, destination country and delivery date. If the model is not determined, please attach the network topology or purchase list.

Check the complete switch model number, parts label and purchase list

Summary

Translate network requirements into a complete BOM that can be accepted

  • Determine the campus or data center role first, and then enter the appropriate family.
  • Use the complete model number, part number and software version instead of the series abbreviation to place your order.
  • Put PoE, power supplies, optics, stacking and licensing in the same list.
  • Perform unit-by-unit inspections of second-hand and discontinued equipment and prepare replacement plans.

The soundest procurement is not about chasing the biggest specs, but about having every capability proven in the target topology, field power, management platform and acceptance process.

Procurement consultation

Submit your Huawei switch listing

Please indicate the complete model, quantity, ports/PoE, software and authorization, device condition, destination country and delivery date; the topology and number of terminals can be described if the model is not specified. Please do not submit passwords or sensitive configurations on the live network.

Switches, optical modules and accessories are undergoing professional procurement inspection

Get in Touch

Tell Us What You Need

Tell us the brand, exact model, specifications, condition, quantity and destination. For accessories and parts, include part numbers and compatibility requirements so we can review each item.

  • E-mailsupport@krlinktech.com
  • Phone+86 17784415683
  • WhatsApp+86 17784415683
  • WeChat+86 17784415683
Contact on WhatsApp